Sahabat teknisi, untuk posting kali ini saya akan coba share sedikit kepada rekan-rekan mengenai failure code yang ada pada unit merek Doosan atau yang dahulu kita kenal dengan nama Daewoo. Saya mengambil merek Doosan karena saya lihat sekarang ini merek ini sudah banyak mewabah di kalangan usaha alat berat.
Berikut ini merupakan beberapa failure code untuk unit Doosan S500-LC.
Code
|
Contents
|
Cause
|
Operation
|
Reset Procedure
|
82
|
Communication Err!!
|
Communication error between e-EPOS controller and instrument panel
|
* Note
|
Automatic reset when problem is corrected
|
01
|
EPPR v/v short
|
Short Circuit
|
Cut off output
current (0 mA)
|
After correcting problem, turn start switch
|
02
|
Press Up s/v short
|
Short Circuit
|
||
03
|
Swing pri. s/v short
|
Short Circuit
|
||
11
|
EPPR v/v open
|
Open Circuit
|
Automatic reset
when problem is corrected |
|
12
|
Press Up s/v open
|
Open Circuit
|
||
13
|
Swing pri. s/v open
|
Open Circuit
|
||
21
|
Dial Voltage Err (H)
|
Output voltage Over 4.6±0.2 V
|
||
22
|
Dial Voltage Err (L)
|
Output voltage Over
0.4±0.2 V |
||
23
|
TPS Voltage Err (H)
|
Output voltage Over 4.6±0.2 V
|
Cut off EPPR v/v
current (0 mA)
|
|
24
|
TPS Voltage Err (L)
|
Output voltage Over 0.4±0.2 V
|
Cut off EPPR v/
v current (0 mA) |
|
25
|
Fpump Sensor Err (H)
|
Output voltage Over 4.6±0.2 V
|
||
26
|
Fpump Sensor Err (L)
|
Output voltage Over 0.4±0.2 V
|
||
27
|
Rpump Sensor Err (H)
|
Output voltage Over 4.6±0.2 V
|
||
28
|
Rpump Sensor Err (L)
|
Output voltage Over 0.4±0.2 V
|
||
29
|
Speed Sensor Err
|
Under 1067±20Hz (On condition that alternator output exceeds over
12±1V)
|
||
31
|
Fuel shot to GND
|
Sensor’s resistance between two terminals is under 150±100W
|
||
32
|
Fuel Sensor open
|
Sensor’s resistance between two terminals is under 6.5±0.5 kW
|
||
33
|
Alternator too high
|
Output voltage of
alternator exceeds 33 V for more than 3 seconds |
||
34
|
Alternator too low
|
When the output voltage is maintained under 18±1 for more than 3
seconds (On condition that speed sensor output exceeds over 1,067Hz)
|
Note:
1. If a communication error is
generated during operation, the power mode, work mode and auto idle mode will
be maintained at the last mode setting before the failure took place until the
unit is shutdown.
2. When start
switch is turned to the "ON" position during a period of a
communication error, the e-EPOS controller will operate in the following modes.
• Power mode: Standard mode
• Work mode: Digging mode
• Auto idle: "ON"(Selection state)
3. The above mentioned two statuses are applicable
to normal condition of an e-EPOS controller.
4. Under the abnormal
condition of an e-EPOS controller, communication cable or instrument panel
failure,"Failure code: 82" can be generated.